Skip to main content
Home > Products > Consumables > SMART™ Micropipettes
SMART Micropipettes for IVF

SMART™ Micropipettes

The SMART™ Micropipettes are intended for use in Assisted Reproduction Technology (A.R.T.) procedures including handling and micromanipulation of spermatozoon, oocytes and embryos.

Features & Benefits

  • All pipettes are made from borosilicate glass.
  • For sterilization, the products are gamma-irradiated and single-packed.
  • Expiration date is 3 years from the date of manufacture.
  • A Certificate of analysis (CoA) for each lot number is available on our website or upon request.
  • Intelligent ICSI Micropipettes
  • Brilliant Biopsy Micropipettes
  • Expert Holding Micropipettes

The injection pipette is intended for aspiration and injection of a spermatozoon into an oocyte. Available with a spiked or beveled tip, at angles between 0° – 45°, and with an inner diameter between 4.5 – 7 µm. Packaged 10 per box.

ID Size:

45 = 4.5 um

50 = 5.0 um

55 = 5.5 um

70 = 7.0 um

Angle Degree:

0 / 5 / 10 / 15 / 20 / 25 / 30 / 35 / 40 / 45

Tip to Elbow:

A = .55 mm

B = 1.00 mm

C = 2.00 mm

D = 0.75 mm

Feature Type 1
Feature Type 2
Feature Type 3

Part Number Description

ICSI Style ● Feature Type ● ID Size* ● Angle ● Tip to Elbow Length

Reference CodePipette TypeAngleIDTip to Elbow
IC.1.45.0.AICSI0 deg.4.5 um0.55 mm
IC.1.45.0.BICSI0 deg.4.5 um1.00 mm
IC.1.45.0.CICSI0 deg.4.5 um2.00 mm
IC.1.45.0.DICSI0 deg.4.5 um0.75 mm
IC.1.45.5.AICSI5 deg.4.5 um0.55 mm
IC.1.45.5.BICSI5eg.4.5 um1.00 mm
IC.1.45.5.CICSI5 deg.4.5 um2.00 mm
IC.1.45.5.DICSI5 deg.4.5 um0.75 mm
IC.1.45.10.AICSI10 deg.4.5 um0.55 mm
IC.1.45.10.BICSI10 deg.4.5 um1.00 mm
IC.1.45.10.CICSI10 deg.4.5 um2.00 mm
IC.1.45.10.DICSI10 deg.4.5 um0.75 mm


The biopsy pipette is intended to biopsy blastomeres or trophectoderm cells from embryos for Preimplantation Genetic Diagnosis (PGD), as well as polar body biopsy. Blastomere and trophectoderm biopsy micropipettes are available with a blunt or beveled tip, at angles between 0° – 45°, and with an inner diameter between 20 – 45 µm. Polar body biopsy micropipettes have a spiked, beveled, or blunt tip, at angles between 0° – 45°, and with an inner diameter of 15 µm. Packaged 10 per box.

ID Size:

15 um / 20 um / 25 um / 30 um / 35 um / 40 um

Angle Degree:

0 / 5 / 10 / 15 / 20 / 25 / 30 / 35 / 40 / 45

Tip to Elbow:

.55 mm for all

Biopsy – Blunt

Blunt = BLU

Beveled = BEV

Polar Body = SPK

Reference CodePipette TypeAngleIDTip to Elbow
BP.20BLU.15Biopsy0 deg.4.5 um0.55 mm
BP.20BLU.15Biopsy0 deg.4.5 um1.00 mm
BP.20BLU.15Biopsy0 deg.4.5 um2.00 mm
BP.20BLU.15Biopsy0 deg.4.5 um0.75 mm
BP.20BLU.15Biopsy5 deg.4.5 um0.55 mm
BP.20BLU.15Biopsy5eg.4.5 um1.00 mm
BP.20BLU.15Biopsy5 deg.4.5 um2.00 mm
BP.20BLU.15Biopsy5 deg.4.5 um0.75 mm
BP.20BLU.15Biopsy10 deg.4.5 um0.55 mm
BP.20BLU.15Biopsy10 deg.4.5 um1.00 mm
BP.20BLU.15Biopsy10 deg.4.5 um2.00 mm
BP.20BLU.15ICBiopsyIS10 deg.4.5 um0.75 mm

The holding pipette is intended for holding an oocyte or embryo during micromanipulation. Available with a polished tip, at angles between 0° – 45°, with an outer diameter of 70 – 180 µm, and with an inner diameter between 10 – 30 µm. Packaged 10 per box.

ID Size:

S = (slim 10 – 15 um)

N = (normal 15 – 20 um)

B = (broad 25 – 35 um)

Angle Degree:

0 / 5 / 10 / 15 / 20 / 25 / 30 / 35 / 40 / 45

Tip to Elbow:

.65 mm for all

Reference CodePipette TypeAngleIDTip to Elbow
BP.20BLU.15Expert Holding0 deg.4.5 um0.65 mm
BP.20BLU.15Expert Holding0 deg.4.5 um0.65 mm
BP.20BLU.15Expert Holding0 deg.4.5 um0.65 mm
BP.20BLU.15Expert Holding0 deg.4.5 um0.65 mm
BP.20BLU.15Expert Holding5 deg.4.5 um0.65 mm
BP.20BLU.15Expert Holding5eg.4.5 um0.65 mm
BP.20BLU.15Expert Holding5 deg.4.5 um0.65 mm
BP.20BLU.15Expert Holding5 deg.4.5 um0.65 mm
BP.20BLU.15Expert Holding10 deg.4.5 um0.65 mm
BP.20BLU.15Expert Holding10 deg.4.5 um0.65 mm
BP.20BLU.15Expert Holding10 deg.4.5 um0.65 mm
HP.70S.Expert Holding10 deg.4.5 um0.65 mm

Resources