Caution: For US CLinical Use: Federal law restricts this device to sale by or on the order of a physician or a practitioner trained and certified in its use. Assisted Hatchling, Embryo Biopsy and PGD are not recommended for routine use in all IVF patients.

LYKOS Laser

 

LYKOS™ Specifications

View PDF Spec Sheet

Laser
Type: 1460 nm, Infrared Solid State Diode
Power: 300 mW @ focus (Class I)
Laser Pulse Length: Adjustable from 1 microsecond to 3000 microseconds, Pulse slider resolution - 1, 10, and 100 microsecond intervals
Laser Power: Adjustable from 1% to 100%
Laser Mode: Laser Mode: Clinical Mode: High, Medium, Low
Firing: By mouse or footswitch
Aiming Marker: Circle or arrow, adjustable “Blink Time” after firing. Isotherm Rings, showing peak temps and hole size.
Crosshairs: Activation, size and color set by user (used for positioning embryo and moving automatic stage)
Laser Alignment: Aligned and locked in place at factory. No on-site laseer alignment required.
Target Alignment: Performed interactively on-screen

Objective

Standard: 40x, 0.60 N.A., I.R. High transmission in the UV [>350 nm], visible and near-infrared, long working distance
Correction: Infinity corrected for 1 mm thick polystyrene Petri Dish, on 500 μm glass heating plate. A nose cap corrector is available if use without the glass heating plate is required.
Working Distance: 1.7 mm to glass heater plate
Parfocality: < 40 µm
Compatibility: 3 RMS thread adapters permit installation on all major microscope models

RED-i Target Locator
Source: Red LED built into laser module
Alignment: X-Y mechanical adjustment to center of laser
beam using Isotherm Rings as guide
Intensity: On-screen intensity adjustment

Video
Camera: High Resolution Color Analog or Digital
Input: Video capture board, internal
Screen Resolution: Desktop: 1024 x 768. Laptop: 1280 x 1024
Image Area: Desktop: 640 x 480pixels. Laptop: 1024 x 768
Zoom: 2x, 4x and 8x, with image panning (user defined increments); Laser may be fired under zoom.
Illumination: Microscope, image on screen

Laser Safety
Class I Laser: Laser pulse and energy cannot exceed Class I limits.
Energy: Once energy level is selected in Clinical mode, other energy levels are deactivated.

Image Capture
Capture and store unlimted images. Images may be stored in JPG, BMP, or TIF format. Manual and automtaic imge file naming. Image Toolbox included (add text, shapes, and measurements to any captured image)

Double Validation Panel
Set two separate power and pulse length combinations

Image Capture and Storage Utility
Capture and store unlimited images. Images stored in user-selected JPG, BMP, or TIF format. Capture unlimited thumbnail images and select which to save. Automatic image capture on laser fire. Manual or automatic file naming. Images may be saved with graphic overlay.

Real-time Video Capture
Record and store video in .avi format. Ability to set maximum recording length. Automatic and manual file naming options.

Time-lapse Video Capture
Record and store video in .avi format. Ability to define capture interval and set maximum recording length. Automatic and manual file naming options.

Documentation Features

Measurement Toolbox
Tools allow measurement of various embryo parameters on captured images. Each measure visible as graphic overlay, including length in micron
Zona: 5 zona thickness measurements; Mean & Standard Deviation
Embryo: 2 diameter measurements; Mean & Standard Deviation; Blastomere count.
Pronuclei: 2 diameter measurements for two separate pronuclei; Mean for each pronuclei
Drill: 5 hole size measurements; Mean & Standard Deviation
Ruler: 5 user-defined measurements Mean & Standard Deviation

Reports and Output
Data Input: Patient Data from keyboard; Data from measurements; Input critical fields from ASCII file
Patient Record: Patient information, treatment identifiers, before and after treatment images, embryo evaluation data
Output: Printout of Patient Record; Patient Record stored in JPG format; ASCII output of all numerical and alphanumeric fields in TXT and MER formats (IDS, Recdate compatible)

Annotation Capabilities
Add text, ellipses, rectangles, lines to captured images. Measue any area of image with ruler tool. Custom select font, color and line widths.

Compatibility
All brands/models of inverted microscopes (no laser module customization needed)
Manipulators
Fluorescence

Dimensions H x W x D in. (mm) / lb (kg)

LYKOS Objective: 1.65 (42) x 1.26 (32) x 1.26 (32) / 0.28 (0.13)
Controller: 3.8 (95) x 2.5 (63.5) x 1.8 (46) / 1.0 (0.45)
Desktop Computer: 16.1 (408) x 7.4 (187) x 17 (433) / 26.5 (12)
Monitor: 13.5 (343) x 17.5 (444) x 1.5 (38.1) / 17.0 (7.7)
Laptop Computer: 1.3 (3.3) x 15.3 (388) x 9.9 (251) / 6.2 (2.8)

Electrical
Input Voltage: Desktop: 100/240 VAC, Monitor: 110-240 VAC, Laptop: 100-240 VAC
Power: Desktop: 300 W, Monitor: 30 W, Laptop: 90W
Line Frequency: Desktop: 50/60 Hz, Monitor: 50/60 Hz, Laptop: 50/60 Hz

LYKOS Computer Specifications (subject to change without notice)
Type Desktop Laptop
O.S. Windows 7 Professional Windows 7 Professional
CPU Pentium Dual Core 3 GHz or Core i5 Intel Core i5
Memory 2 GB DDR 4 GB
Drives

250 GB HD
16x DVD+/-RW SATA

250 GB HD
8x DVD+/-RW
Display 20" flat panel 15" (typical), XGA
Ports Serial, Parallel, USB 2.0, PS/2 Parallel, USB 2.0, VGA, 1394, HDMI, Memory card reader
Network 10/100 Mps Ethernet 10/100 Mps Ethernet
Wireless Network (802.11bg)

 

Return to Top